Circuit Breaker

Contactor

Relay

Distribution Board

Push Button Switches

Meters

Fuses

Power Inverter

Industrial Sockets and Plug

Waterproof Switch

Temperature Controller

Automatic Transformer Switch

Energy Saving Lamp

Automatic Voltage Regulator & UPS

Cable Accessories

Electrical Accessories

Wall Switch

Location: Home Page >> Contactor >> MBC-4X AC Contactor

back
MBC-4X AC Contactor

MBC-4X AC Contactor - Contactor

 

Application:
MBC-4XU00CY definite purpose contactors (4-pole,20A ) are ideal for(HVAC) air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, lighting, pools & spas and food service equipment.

Product Feature:
1.Unique amortization system to eliminate contact bounce
2.Low cost
3.Accessories modification quickly and easily without using tools
4.Various kinds of terminals for customers' special requirements
5.Easy to change the coil
6.General amounting size, easy for replacement
7.Can be combined with a thermal overload relay to form an electromagnet starter to protect the line in which overload operation may occur
8.Double E magnet assembly providing optimal performance with reduced power consumption
9.Effective dustproof cover available
10.Silver Cadmium Oxide contacts provide long electrical endurance.
11.Class F high temperature insulated coils are standard.

Specifications:

NUMBER
OF
POLES
COIL
VOLTAGE
50/60HZ
FULL
LOAD
AMPS
LINE VOLTAGE LOCKED ROTOR AMPS RESISTIVE SMPS RATING MAXIMUM HORSEPOWER BOX QUANTITY APPROX UNIT WEIGHT
VOLTAGE SINGLE
PHASE
THREE
PHASE
25FLA-4POLE
4 24
110/120
208/240
277
25 240/277
480
600
 
150
125
100
 
35
35
35
 
110/120
200/208
240/277
480
2
-
5
-
-
7.5
10
15
20 .68 kg
30FLA-4POLE
4 24
110/120
208/240
277
25 240/277
480
600
 
180
150
120
 
40
40
40
 
110/120
200/208
240/277
480
2
-
5
-
-
10
10
15
20 .68 kg
40FLA-4POLE
4 24
110/120
208/240
277
40 40/277
480
600
 
240
200
160
 
50
50
500
 
110/120
200/208
240/277
480
3
-
7.5
-
-
10
10
10
20 .68 kg

OTHER SPECIFCATIONS 20-30 FLA 40 FLA
Line and Load Terminals #10-32 screw* Box Lug
Wire Size AWG Min-Max 16-8** 14-4 Cu/AL
Tightening Torque(Recommended) 22 in ibs 40 in ibs
Quick Connects:power Termainals Coil Termainals Dual 250 QC
Dual 250 QC(2)***
Dual 250 QC
Dual 250 QC(2)***
Covers Optional Standard
Insulation System 130 Class B 130 Class B
*Stranding must be split for #8 wirt. **(1)#6-32 screw and (1).250QC are optional.***Permissible Ambient Temperature: -40/65 -40F/150F

COIL TECHNICAL DATA 50/60hz MBC Series
Nominal Coil Voltage 24 120 208/240 277 480
Maximum Pickup Volts 19.2 88 177 220 384
Drop-Out Volts Range 6-15 20-70 40-140 65-185 150-270
Nominal Inrush VA@50Hz 68 68 58 58 48
Nominal Inrush VA@60Hz 60 60 55 52 52
Nominal Sealed VA@50Hz 14 14 11 11 11
Nominal Sealed VA@60Hz 9 9 9.5 9.5 9
Nominal DC Resistance-Ohms 5 148 550 750 2100

Dimensions:
MBC-4X Dimensions - Contactor


back