HY125 Contactor Special For Capacitor

General Description:
XD1 type current-limiting reactor is a kind of dry reactors cast into formation with unsaturated polyester resin. lt's suitable for mounting in the PGJ1 or other types of low voltage reactive power compensation screen to limit the instantaneous flashy flow as a capacitor.
Service Conditions :
1. Altitude is no more than 2500 meters.
2. Ambient temperature:-15
+40
3. Relative humidity:At 40
,50%; At 20
, 90%
4. No corrosive gas,conductive dust,inflammable and explosive medium surrounded.
5. No violent vibration at mounting position.
Summary:
HY125 contactless switch is the electronic power unit for rapid transferring of power parallel capacitor, the electric structure is composed of high power inverse parallel crystal tube module, isolation circuit, trigger circuit, synchronous circuit, protection circuit and driving circuit, includes on or off connecting terminal of control switch, control logic voltage OV(off), 1 2V(on). The switch has many merits of simple installation, convenient maintenance,rapid response,no surge at transferring,no noise,reliable and stable property,phase-failure protection.It is the ideal unit of transferring capacitance bank for reactive power dynamitic compensating device.
Dimensions:

General Description:
CJ16(19)switch-over capacitor contactor is the new type of components for electric appliances, which is developed and produced on the basis of the introduced foreign technology of the same kind. The device is widely applied to the low voltage reactive power compensation screen to replace the subassembly composed of three XD1 current-limiting reactors and a CJ10 contactor, and it is also can be used in the general control circuit to limit flashy flow.
Specifications:
- Rated voltage:380V(220V)
- Rated frequency:50Hz
- Control uolume:380V,1Kvar30Kvar
- 220V,1Kvar---10Kvar
| Model | CJ19-32 CJ1632① |
CJ19-43 CJ1643① |
CJ19B32 CJ19C32① |
CJ19B-43 CJ19C43① |
CJ19B-63 CJ19C63① |
|||||
| 400V Controlled 400V |
Output | 18(16)③ | 20 | 15 | 20 | 32 | ||||
| Rated voltage(A) | 26(23) | 29 | 21.6 | 29 | 46 | |||||
| Working current 1.3 In A | 33.8(30) | 37.7 | 28 | 37.7 | 60 | |||||
| Conventional heating currentlthA | 32 | 43 | 32 | 43 | 69 | |||||
| Controlling capability to flashy flow | 20ln | |||||||||
| Coil | Working voltage Us 50Hz | 220,380 or according to users'requirements | ||||||||
| Operating range | 0.85 1.1Us |
|||||||||
| Consumed start Power holding (VA) |
68 12 |
115 11 |
200 20 |
|||||||
| Rated current for short-circuit protected fuse |
1.5 2.5In |
|||||||||
| Rated insulation voltage Ui 50Hz V |
500 | 660 | ||||||||
| Conventional heating current of auxiliary contacts AC15A |
10 | |||||||||
| Mechanical life ten thousand times |
100 | 80 | ||||||||
| Electrical life Operating frequency 120 1/hten thousand times |
10 | 8 | ||||||||
| Weight kg | About0.58 | About0.57 | About0.6 | About1.25 | ||||||
| Model | Contactor model |
Auxiliary contact |
Quantity | Mark | ||||
| Normal open (Make) |
Normal close (break) |
|||||||
| 400V Controlled 400V |
Output | |||||||
| Rated voltage(A) | CJ19-32/43 | 20E | 2 | - | 11.12 21.22 |
- | ||
| Working current 1.3 In A | 02E | - | 2 | - | 11.12 21.22 |
|||
| Conventional heating currentlthA | 11E | 1 | 1 | 13.14 | 21.22 | |||
| Controlling capability to flashy flow | 21E | 2 | 1 | 13.14 33.34 |
21.22 | |||
| Coil | Working voltage Us 50Hz | 12E | 1 | 2 | 13.14 | 2121.22 31.32 |
||
| Operating range | ![]() |
|||||||
| Consumed start Power holding (VA) |
||||||||
| Rated current for short-circuit protected fuse |
||||||||
| Rated insulation voltage Ui 50Hz V |
||||||||
| Conventional heating current of auxiliary contacts AC15A |
||||||||
| Mechanical life ten thousand times |
||||||||
| Electrical life Operating frequency 120 1/hten thousand times |
||||||||
| Weight kg | ||||||||
Dimensions:

Next Page: HY-JKL Reactive Power Compensated Controller