FAQs Contact Us Catalogue Download paypal
Location: Home Page >> Others >> Switch Power Supply >> DR-120-12 Switch Power Supply

DR-120-12 Switch Power Supply

Description
- Competitived price and high reliability
- 105 output capacitor
- AC input power suitable for the world
- High efficiency and low operation temperature
- Soft-start current can reduce the AC input impact effeciticly
- With short-circuit and overload protection
- Compact size, light weight
- 100% full-load burn-in test
- Installed with EMI filter, minimum wave

Model DR-120-12
DC output voltage 12V
Output voltage range(Note:2) 2%
Rated output current 10A
Output current range 0-10A
Wave and noise(Note:3) 80mVp-p
Inlet stability(Note:4) 0.5%
Load stability(Note:5) 1%
DC output power 120W
Efficiency 80%
Adjustable range for DC voltage 10.813.2V
AC input voltage range 88132VAC 4763Hz;240370VDC
Input current 3.3A/115V 2A/230V
AC inrush current Cold-start current 30A/115V 60A/230V
Leakage current 3.5mA/240VAC
Overload protection 105%150% Type: pulsing hiccup shutdown Reset: tuto recovery
Over-voltage protection 13.816.2V
High-temperature protection 855(TSW1)
Temperature coefficient 0.03%/(050)
Setup, rise , hold up time 500ms,70ms, 50ms/230V
Vibration 10500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltage Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC
Isolation resistance Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity -10+60(Refer to output derating curve), 20%90%RH
Overall dimension 65.5125.2100mm
Weight 0.81Kgs 20PCS/14Kg/1.1CUFT
Safety standards Meet UL 1012 requiement (Not apply for the mark)
EMC standards Meet FCC PART 15 J Conduction class B

Note
1. The testing condition for the paramenter above is: 230VAC input, rated load, 25 70% RH. Temperatuer.
2. Error: include the setting error, line stability and load stability.(Note:5)
3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: The load is from 0% to 100%